| Name of product | | NIRO-200NX Oxygenation Monitor |
 Click image to enlarge |
| |
|
|
| |
| Key Specifications |
| Part Number |
C10448 |
| Name of product |
NIRO-200NX Oxygenation Monitor |
| Brief description |
Noninvasive NIRS Monitor for cerebral and muscle oxygenation, providing quantitative data (SRS) and relative Beer-Lambert values. Dual channel system. |
|
Full description |
|
The NIRO-200NX Monitor is a quantitative oxygenation monitor for cerebral tissue and muscle tissue; using the spatial resolved spectroscopy method (SRS) it can provide the quantitative data for tissue oxygenation index (TOI) in % and for tissue hemoglobin index (THI) in a.u., the latter one also can be displayed as normalized THI (nTHI) which stands for the percentage change of total hemoglobin; NIRO-200NX additional uses the Beer-Lambert method and provides at same time the relative changes of delta O2Hb, delta HHb and delta cHB in microMolar. This simultaneous use of SRS and Beer-Lambert data thus delivers a detailled description about the hemodynamic situation. As it is a two channel system bihemispheric data can be achieved. Besides of real-time graphic display also real-time data transfer to an external computer is realized. For stand alone use of the NIRO-200NX its data can be stored on an USB stick. Due to online checking of the measurement conditions plus the simultaneous use of SRS and Beer-Lambert method the system allows a redundance check of the data (data reliability) plus enables hemodynamic information for any saturation changes. The NIRO-200NX can measure up to a speed of 20Hz. Combined with indocyanin green bolus the blood flow index (BFI) can be measured too. |
|
Features |
- Measured parameters are TOI, THI, nTHI, delta O2Hb, delta HHb, delta cHb
- two channel system
- time resolution selectable from 20Hz to 30 sec.
- realtime data trasfer to PC
- USB storage off line
- analog output
- Philips Vuelink format
- emitter and detector are reusable, no running costs
- battery function
|
|
Applications |
- Monitoring of cerebral and muscle tissue oxygenation in many different medical disciplines interoperatively as well as in ICUs
- study of influences onto the cerebral hemodynamics by means of patients treatment or manipulation, of drug effect, of ventilation, of stimulation, for autoregulation studies, etc.
|
| Related Products |
NIRO-200NX |
|
Standards Compliance |
|
The NIRO-200NX is for investigational use only. It has not been cleared or approved for use by the U.S. Food and Drug Administration, and it is not intended for diagnostic use. The NIRO-200NX may be used for investigational use only in accordence with FDS regulations and in accordance with any applicable institutional requirements.
In accordance with the European MDD regulations, approoved by SGS notified under no. 0120 to the EC commission. |
| Notification |
LCD monitor lamp(s) Contains Mercury, Dispose According to Local, State or Federal Laws. |
|
| |
|
|