| Part Number | Name of product | Abstract | | C9100-13 | ImagEM (Back-Thinned Electron Multiplier CCD Camera) | Cooled CCD with a resolution of 512 x 512 pixels for long integration or real time imaging featuring high sensitivity, high stability, and low noise. |
 Click image to enlarge |
The ImagEM Enhanced is a brand new member of the C9100 camera series. Combining our decades of experience with high vacuum technology and all the latest advances in CCD circuit design this new camera offers application independent imaging. From the very brightest high dynamic range applications to single photon imaging over long integrations, this camera provides images with the very best signal to noise ratios. The key to this versatility is the E2V CCD97 CCD and Hamamatsu creative engineering. New methods for driving this well known CCD offer special modes of operation for fast, low noise operation and special patent pending synchronization with spinning disk confocal and multi-point confocal microscopes.
With both on-chip multiplication and normal CCD readout amplifiers, a choice of readout speeds is included to match the signal to noise requirements of the application. New on-board signal processing features provide a choice of real time frame averaging, background subtraction with offset and shading correction. Unmatched cooling and cooling stability provided the very best in quantitative data collection even at high frame rates. For all your applications, ImagEM Enhanced.
|
| |
|
|
| |
| Key Specifications |
Typical Spectral Response |
| Part Number |
C9100-13 |
| Name of product |
ImagEM (Back-Thinned Electron Multiplier CCD Camera) |
|
Features |
- -90 °C cooling with hermetic sealed head
- Air or water cooled
- Gain stability/Temperature stability
- Dual readout mode
- Multiple pixel clock selection
- Photon imaging mode (Patent pending)
- Real time image processing
- External trigger/Synchronous readout trigger (Patent pending)
- Programmable trigger signal output
- Multiple heads capability
|
|
Applications |
- Intracellular ion imaging
- Intravital fluorescence microscopy and blood flow studies
- Fast tracking of small particles
- Single molecule observation at the photon level
- High speed fluorescence cell tomography
- High dynamic range brightfield imaging
- NIR and NIR DIC imaging
- Luminescence imaging
|
| Imaging device |
Back-thinned Frame transfer CCD |
| Wavelength (min.) |
350 nm |
| Wavelength (max.) |
1050 nm |
| QE (max.) |
92% |
| Active pixels |
512(H) x 512(V) |
| Pixel size |
16(H) x 16(V) µm |
| Active sensor area |
8.192(H) x 8.192(V) mm |
| Pixel clock rate (max.) |
EM-CCD mode: 11 MHz, 2.75 MHz, 0.69 MHz |
| Multiple pixel clocks |
Normal CCD mode: 2.75 MHz, 0.69 |
| Frame rate (max.) |
Fastest in EM-CCD mode (with binning and subarray) 31.9 fps to 404 fps |
| Min. exposure |
0.01 msec. |
| Max. exposure |
7200 sec. |
| Sub-array |
Yes |
| Binning |
Yes, 2x2, 4x4 standard (8x8 and 16x16 optional) |
| Full well capacity |
370,000 e-, Max 800,000 e- |
| Dark current |
Forced-air cooled (-65°C) 0.01 e-/pix/sec Water cooled (-80° C) 0.001 e-/pix/sec |
| Read noise (min.) |
EM-CCD Gain 4x: 11 MHz: 25 e r.m.s., 2.75 MHz: 20 e r.m.s., 0.69 MHz: 8 EM-CCD Gain 1200x: at all clock speeds: <1, Normal-CCD: 2.75 MHz: 17 e r.m.s. , 0.69 MHz: 8 e-r.m.s. |
| A/D converter |
16 bit |
| Dynamic range |
na |
| Cooling method |
Air / Water |
| Cooling temp. |
Air cooling Mode: -65 °C. Water cooling Mode: -79 °C |
| Data interface |
Camera link |
| Monochrome or color |
monochrome |
| Contrast enhancement |
No |
| Lens mount |
C-mount |
| Line voltage |
AC 100 V to 240 V, 50 Hz/60 Hz |
| Power consumption |
140 VA |
| External trigger |
1 |
| Contrast Enhancement |
1 |
| Lens mount |
1 |
|
 Click image to enlarge
Configuration